Utilizza questo identificativo per citare o creare un link a questo documento: http://hdl.handle.net/2307/4406
Titolo: Nonlinear static procedures for analysis and retrofitting of existing buildings with dissipative braces
Autori: Liu, Xu
Relatore: Nuti, Camillo
Parole chiave: Non-linear
static procedures
retrofitting
Data di pubblicazione: 26-giu-2014
Editore: Università degli studi Roma Tre
Abstract: Nonlinear Static Procedures (NSPs), often called pushover analyses, are deemed to be very practical tools to assess the nonlinear seismic performance of structures. The use of NSPs for the seismic assessment of plan regular buildings and bridges is widespread nowadays. The use of NSPs in the case of real existing structures, which are almost always irregular, has so far been studied by a limited number of authors. This fact limits the application of NSPs to assess current existing structures. In order to improve the use of NSPs in practical, the applicability of NSPs for analysis and retrofitting of existing buildings with dissipative braces is evaluated in this thesis. In this work, a more efficient incremental modal pushover analysis (IMPA) to obtain capacity curve of the structure to evaluate the seismic demand is proposed: the procedure allows defining the capacity curve based on the execution of a series of MPAs. The case studies chosen are a benchmark structure as the regular structure and a real existing reinforced concrete building, which shows a strong irregularity in plan and vertical.Comparative evaluation of the different commonly used NSPs, which are Capacity Spectrum Method (CSM) adopted in ATC-40, Displacement Coefficient Method integrated into FEMA356, and N2 method presented in Eurocode 8 and modal pushover analysis (MPA), to describe their relative accurancy and limitations. A displacement based design procedure of dissipative devices for seismic upgrading structures is applied to the exising builidng. The accuracy of the IMPA is evaluated by comparison with IDA curve for the regular and irregular structure. Force-based and displacement design procedure of passive energy dissipation devices are applied to retrofit a school building located in shanghai, the comparisons of the two design methods and the seismic behavior of the retrofitting structure with different passive energy dissipation devices are discussed.
URI: http://hdl.handle.net/2307/4406
Diritti di Accesso: info:eu-repo/semantics/openAccess
È visualizzato nelle collezioni:X_Dipartimento di Ingegneria
T - Tesi di dottorato

File in questo documento:
File Descrizione DimensioniFormato
Xu Liu_thesis.pdf12.25 MBAdobe PDFVisualizza/apri
Visualizza tutti i metadati del documento Suggerisci questo documento

Page view(s)

187
Last Week
0
Last month
1
checked on 22-nov-2024

Download(s)

74
checked on 22-nov-2024

Google ScholarTM

Check


Tutti i documenti archiviati in DSpace sono protetti da copyright. Tutti i diritti riservati.