Abstract: The ATLAS muon spectrometer consists of three layers of precision drift-tube chambers in a toroidal magnetic with a field integral between 2.5 and 6 Tm. Muon tracks are reconstructed with 97% efficiency and a momentum resolution between 3% and 4% for 10 GeV< pT <500 GeV and better than 10% for transverse momenta up to 1 TeV. In this note, the performance of a perfectly calibrated and aligned muon spectrometer will be reviewed and the impact of deteriorations of the magnetic field, the calibration and misalignment of the muon chambers on the performance will be discussed. The main part of the note describes how the performance of the muon spectrometer can be determined using dimuon decays of Z bosons and JPsi mesons
URI : http://hdl.handle.net/2307/524
ISSN : 978-92-9083-321-5
Wuxuu ka dhex muuqdaa ururinnada:C - Capitolo di libro
Dipartimento di Matematica e Fisica

Fayl ku dhex jira qoraalkan:
Fayl Sifayn BaacFayl
ATL-PHYS-PUB-2009-010.pdf1.37 MBAdobe PDFMuuji/fur
Muuji xogta qoraalka Ku tali qoraalkan

Page view(s)

129
Last Week
1
Last month
2
checked on Dec 3, 2024

Download(s)

29
checked on Dec 3, 2024

Google ScholarTM

Check


Dhammaan qoraallada lagu kaydiyay DSpace waxay u dhowrsanyihiin xuquuqda qoraha.